H2/H1D CDI Test
All testing is with analog meter with meter set at Rx1K and meter zeroed when leads are touched together. All CDI leads must be disconnected.
RECTIFIER UNIT TEST
1. Meter + connected to CDI Blk/Wht
Meter - connected to: Grn = 3.9
Blu = 3.9
Wht = 12
Lt Grn (all) = infinity
2. Meter - connected to CDI Blk/Wht
Meter + connected to: Grn = infinity
Blu = infinity
Wht = 90
Lt Grn (all) = 3.9
Any reading substantially different than shown above indicates a defective unit.
UNIT B TEST
SCR Test
1. Meter - connected to CDI Blk (Gnd)
Meter + connected to: Lt Grn = infinity
2. Meter - connected to CDI Wht
Meter + connected to: Lt Grn = infinity
Trigger Diode Test
1. Meter - connected to CDI Blk (Gnd)
Meter + connected to: Wht = infinity
2. Meter + connected to CDI Blk (Gnd)
Meter - connected to: Wht = 4.5
Charge Capacitor Test
1. Meter + connected to CDI Blk (Gnd)
Meter - connected to: Red = infinity
2. Meter - connected to CDI Blk (Gnd)
Meter + connected to: Red = small needle deflection then
infinity
Although any test failed will indicate a defective unit, a passed test will
not guarantee that the unit is good.